Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The fault message and the fault memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For plug-in Model Series167, 206, 214, 223, 247, 254: Carry out software update and SCN coding for the control unit "N83 – AC charger for high-voltage battery (SG-LG)". For model series 243: Carry out software update and SCN coding for the control units "N116/5 – DC charge-connection unit (DCCU)" and "N83/11 – AC charger for high-voltage battery (SG-LG)"

Communications NHTSA ↗

Nous regroupons uniquement les dépôts dont marque, numéro, date et résumé intégral concordent. Identifiants et archives sont conservés ; seuls les remplacements explicites établis sont signalés. Les véhicules antérieurs à 1994 sont séparés des résultats par défaut. Une année non précisée ne signifie pas toutes les années.